POS 20W Constant Voltage LED Driver

12.19 inc. VAT

€9.91 excl. VAT

Please select product variants
Clear
Compare
Availability: Normally Stocked Item, 1 day dispatch
  • quick overview

    • IP20 for indoor applications only
    • Constant voltage design
    • European AC input range
    • Protections: Short circuit / Overload / Over temperature
    • Cooling by free air convection
    • Compliance with worldwide regulations for lighting
    • 12V & 24V DC LED Driver for LED Lighting

  • product details
    Manufacturer POS POS
    SKU FTPC20V12-C FTPC20V24-C
    Dimensions (L x W x H) 103 x 35.5 x 16.5mm 103 x 35.5 x 16.5mm
         
    OUTPUT    
    Output Voltage 12V 24V
    Rated Current 1.67A 0.84A
    Current Range 0 ÷ 1.67A N/a
    Rated Power 20.04W 20.16W
    No Output Voltage (max.) 12.6V N/a
    Ripple & Noise (max.) 200mVP-P 200mVP-P
    Setup, Rise Time 500ms, 20ms / 230VAC at full load 500ms, 20ms / 230VAC at full load
    Hold up Time (typ.) 10ms / 230VAC at full load 10ms / 230VAC at full load
    INPUT
    Voltage Range 180 ÷ 264VAC 180 ÷ 264VAC
    Power Factor (typ.) PF > 0.5 / 230VAC at full load PF > 0.5 / 230VAC at full load
    Efficiency (typ.) 85% 85%
    AC current (typ.) 0.23A / 230VAC 0.22A / 230VAC
    Inrush current (max.) 50A / 230VAC(25°C) 50A / 230VAC(25°C)
    No Load Power Consumption (max.) 0.5W 0.5W
    PROTECTIONS
    Over Current Range 110 ÷ 140% 110 ÷ 140%
    Over Current Type Constant current limiting to 60% rated voltage next hiccup mode. Recovers automatically after fault condition is removed. Constant current limiting to 60% rated voltage next hiccup mode. Recovers automatically after fault condition is removed.
    Short Circuit Type Hiccup mode. Recovers automatically after fault condition is removed Hiccup mode. Recovers automatically after fault condition is removed
    Over Temp Range 110°C ± 10°C 110°C ± 10°C
    Over Temp Type Shut down output voltage. Recovers automatically after fault condition is removed Shut down output voltage. Recovers automatically after fault condition is removed
    Safety Standards Compliance to EN61347-1, EN61347-2-13 , EN 62493 Compliance to EN61347-1, EN61347-2-13 , EN 62493
    Working Temperature -20°C ÷ +45°C -20°C ÷ +45°C
    IP Rating IP20 IP20