POS 200W Constant Voltage IP67 LED Driver

74.93 inc. VAT

€60.92 excl. VAT

Please select product variants
Clear
Compare
Availability: Normally Stocked Item, 1 day dispatch
  • quick overview

    • European AC input / Full range
    • Protections: Short circuit / Overload / Over voltage / Over temperature
    • Cooling by free air convection
    • Built-in active PFC function
    • IP67 design for indoor and outdoor appliances
    • Compliance with worldwide regulations for lighting
    • 12V & 24V DC LED Driver for LED lighting

  • product details
    Manufacturer POS POS
    SKU MCHQ200V12-E
    MCHQ200V24-E
    Dimensions (L x W x H) 221 x 61.5 x 36.5mm
    221 x 61.5 x 36.5mm
         
    OUTPUT    
    Output Voltage 12V DC 24V DC
    Rated Current 16.7A 8.3A
    Rated Power 200.4W 199.2W
    No Output Voltage (max.) 12.6VDC 25.2VDC
    Ripple & Noise (max.) 200mVP-P
    300mVP-P
    Turn-On Delay Time 300ms, 50ms, 5ms 300ms, 50ms, 5ms
         
    INPUT    
    Voltage Range 200 ÷ 277VAC 200 ÷ 277VAC
    Power Factor (typ.) PF > 0.9 / 230VAC at full load PF > 0.9 / 230VAC at full load
    Efficiency (typ.) 90%
    91%
    AC current (typ.) 1.3A / 230VAC
    1.3A / 230VAC
    Inrush current (max.) 75A / 230VAC(25°C)
    75A / 230VAC(25°C)
    Inrush current (max.) <0.5W
    <0.5W
         
    PROTECTIONS    
    Overload Range 105 ÷ 150%
    105 ÷ 150%
    Overload Type fold forward mode (voltage rises, current drops) to 60% rated voltage next hiccup mode. Recovers automatically after fault condition is removed. fold forward mode (voltage rises, current drops) to 60% rated voltage next hiccup mode. Recovers automatically after fault condition is removed.
    Short Circuit Type hiccup mode. Recovers automatically after fault condition is removed. hiccup mode. Recovers automatically after fault condition is removed.
    Over Voltage 15V 30V
    Over Voltage Type: Output voltage limiting to 15V. Recovers automatically after fault condition is removed. Output voltage limiting to 30V. Recovers automatically after fault condition is removed.
    Over Temperature Range: 115°C ± 10°C
    115°C ± 10°C
    Over Temperature Type: Shut down output voltage. Recovers automatically after fault condition is removed Shut down output voltage. Recovers automatically after fault condition is removed
    Safety Standards Compliance to EN61347-1, EN61347-2-13 – TUV certificate Compliance to EN61347-1, EN61347-2-13 – TUV certificate
    Working Temperature
    -40°C ÷ +60°C, max tC = 90°C -40°C ÷ +60°C, max tC = 90°C
    IP Rating IP67 IP67